f.Left Drum Motor

There are two (2) different ways that the left drum motor is connected with or without the motor disconnect junction box. The junction box is used when the connections to the left motor are made on the back side of the motor, nearest to the tumbler (basket). When connecting the motor, bring the left drum motor cable (refer to Section e [Tumbler Junction Box Disconnect] on page 17) and mechanically connect it to the junction box on the motor or the external junction box with the lock nut. There will be four

(4) wires in the cable, match them with the PVC electrical tape. There should be one (1) green wire remaining, which is used for the ground connection. Replace the screws that go on the cover of the junction box. Bolt the safety panel back in place using the six (6) bolts removed in Section e (Tumbler Junction Box Disconnect) on page 17, then bolt the lower left side panel back in to place using the four (4) bolts also removed in Section e (Tumbler Junction Box Disconnect) on page 17.

18

Page 22
Image 22
American Dryer Corp ADG-464 manual Left Drum Motor