AMX NXR-ZGW/-ZRP manual Select the device’s firmware file from the Files section FIG

Models: NXR-ZGW/-ZRP

1 42
Download 42 pages 6.45 Kb
Page 39
Image 39

Device Configuration

3.After the Communication Verification dialog window verifies active communication between the PC and the Master, verify the NXR-ZGW appears in the OnLine Tree tab of the Workspace window. The default device value is 10001.

4.If the device firmware version is not the latest available; locate and download the latest firmware file from the www.amx.com > Tech Center > Downloadable Files > Firmware Files section of the website.

5.Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (FIG. 17). Verify the device’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window.

Selected Firmware file

 

Description field for selected KIT file

 

Firmware download status

Device value and System number must match the values

listed in the Workspace window

FIG. 17 Send to NetLinx Device dialog

6.Select the device’s firmware file from the Files section (FIG. 17).

7.Enter the Device value associated with the device and the System number associated with the Master (listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.

8.Click the Reboot Device checkbox. This causes the NXR-ZGW device to reboot after the firmware update process is complete.

9.Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (FIG. 17). Do not pull power from device during transfer, it can take approximately 5 minutes to finalize firmware transfer. The upgrade can still be in progress when the bargraph reaches the end, it is a good idea to wait until the process is complete.

10.Click Close (after the device reboots) to return to the main program.

11.Right-click the associated System number and select Refresh System. This causes a refresh of all project systems, establishes a new connection to the Master, and populates the System list with devices on your particular system.

NXR-ZGW/-ZRP

33

 

 

Page 39
Image 39
AMX NXR-ZGW/-ZRP manual Select the device’s firmware file from the Files section FIG