TroubleshootingSymptom Charts/System - 4

System

Does not power on;

1

Check cables.

screen is black, fan is

2

Plug monitor directly into wall socket, and verify that

not running and LED

3

monitor has power.

isnotlit

Reset logic board. (Refer to Additional Procedures.)

 

4

Reseat ROM SIMM and cache SIMM.

 

5

Replace power cord.

 

6

Replace power supply.

 

7

Replace logic board.

Clicking, chirping or

1

Replace power supply.

thumping

2

Replace logic board. Retain customer’s SIMMs.