2.2 ALARM I/O

1.ALM-OUT A

7.RS-485:D+

2.ALM-OUT B

8.RS-485:D-

3.ALM-IN +

9.DC-OUT(5V)

4.ALM-IN -

10.GND

5.ALM-RST +

11.AUDIO-IN

6.ALM-RST -

12.AUDIO-OUT

1 & 2.

ALARM OUT (OUTPUT): This is an alarm output trigger. Connect this to external

 

devices such as buzzers or lights. (

 

 

5V, 20mA

 

 

 

0V(Active) )

 

 

 

3 & 4.

ALARM IN (INPUT): This is an alarm input that can be programmed in the menu

 

 

 

 

 

 

 

 

5V, 20mA

 

system to active low. (

 

 

0V(Active) )

 

 

 

5 & 6.

ALARM RESET (INPUT): This pin connects to an alarm-clear device for clearing an

 

 

 

 

5V, 20mA

 

 

 

 

alarm. (

 

 

0V(Active) )

 

 

 

 

 

 

 

 

 

7.RS-485 D+

8.RS-485 D-

9.DC OUT (5V)

10.GND: Ground contact.

11.AUDIO IN

12.AUDIO OUT: This provides the unit’s audio signal to a speaker.