Ariston 47-116-15 Removing the safety valve, Removing the automatic air vent

Models: 47-116-15

1 57
Download 57 pages 20.72 Kb
Page 36
Image 36

Removing the safety valve

1.Loosen nut “Z” (FIG. 1.36);

2.Unscrew and remove the valve (FIG. 1.37).

Z

40.eps

FIG. 1.36

 

 

37.eps

FIG. 1.37

Removing the automatic air vent

1.Unscrew valve top “A1” (FIG. 1.38);

2.Remove valve (Fig 1.39).

A1

39.eps

Fig. 1.38

 

 

41.eps

Fig. 1.39

Removing the main circuit flow switch

1.Remove the cable of the main circuit flow switch “B1” (FIG. 1.40);

2.Remove the screws “C1” (FIG. 1.41);

3.Remove the main circuit flow switch.

B1

FIG. 1.40

53.eps

C1

 

C1

 

 

FIG. 1.41

54.eps

12

B063

Page 36
Image 36
Ariston 47-116-15 Removing the safety valve, Removing the automatic air vent, Removing the main circuit flow switch