Ariston 47-116-15 installation instructions Regulating the heating power for Natural gas G20

Models: 47-116-15

1 57
Download 57 pages 20.72 Kb
Page 33
Image 33

Regulating the heating power for

natural gas (G20)

model 23

model 27

CG007A

Regulating the heating power for

 

butane gas (G30)

model 23

 

 

model 27

 

CG008A

Regulating the heating power for

 

propane gas (G31)

40

 

 

38

 

36

 

34

 

model 23

 

model 27

 

 

 

CG009A

TABLE “A”

 

 

 

MFFI

2.70

2.01 Kg/h

2.00 Kg/h

 

 

 

23

1.16

0.87 Kg/h

0.85 Kg/h

20

28 mbar

37 mbar

 

 

11.0

27.7 mbar

35.5 mbar

 

2.0

6.0 mbar

7.3 mbar

 

 

12 x 0.77

12 x 0.77

MFFI

3.15

2.34 Kg/h

2.31 Kg/h

 

 

 

27

1.26

0.94 Kg/h

0.93 Kg/h

20

28 mbar

37 mbar

 

 

11.0

27.7 mbar

35.5 mbar

 

1.6

4.6 mbar

6.0 mbar

 

14 x 1.30

14 x 0.77

14 x 0.77

 

 

 

TB012A