Ariston 47-116-15 installation instructions Electrical Diagrams

Models: 47-116-15

1 57
Download 57 pages 20.72 Kb
Page 47
Image 47

3.ELECTRICAL DIAGRAMS

LEGEND:

A= Time Clock Connector

B= Central Heating Selection (Winter) and Temperature Adjustment

C= Connector for Total Check System

D= Domestic Hot Water Temperature Adjustment

E= Soft-light Adjustment

F= Maximum Heating Adjustment

G= On/Off Switch

H= On/Off L.E.D.

I= Fume Sensor L.E.D.

J= Ignition Failure (Lockout) L.E.D.

K= Low System Water Level/Lack of Circulation L.E.D.

L= Reset Button

M= Economy/Comfort Selector

N= Overheat L.E.D.

O= Temperature L.E.D.s

P= Transformer

Q= Circulation Pump Relay

R= Fan Relay

S= Gas Valve Relay

T= Motorised Diverter Valve Relay

V

=

Spark Generator

U

=

Anti-cycling Device Adjustment for Heating

A01

=

 

Circulation Pump

A02

=

 

Fan

A03

=

 

Spark Generator/Gas Valve Supply

A04

=

 

Motorised Diverter Valve

A05

=

 

Flame Detection Circuit

A06

=

 

Detection Electrode

A07

=

 

Main Circuit Temperature Probe

A08

=

 

Domestic Hot Water Temperature Probe

A09

=

 

Domestic Hot Water Flow Switch

A10

=

 

Main Circuit Flow Switch

A11

=

 

Modulator

A12

=

 

Air Pressure Switch

A13

=

 

Safety Thermostat

A14

=

 

External (Room) Thermostat

Colours:

 

Gry

 

=

Grey

Wh

 

=

White

Pnk

 

=

Pink

Brn

 

=

Brown

Bl

 

=

Blue

Blk

 

=

Black

Rd/Blk

=

Red/Black

B063

23

Page 47
Image 47
Ariston 47-116-15 installation instructions Electrical Diagrams