F-50

F-50

TROUBLESHOOTING & REPAIR

CONTROL PC BOARD TEST (continued)

CONTROL PC BOARD VOLTAGE TEST POINTS CHART

 

 

 

Special

 

 

 

 

Signals Being

Expected

Conditions

Test Points

Checked

Reading

for Test

 

 

 

 

3J13 to 5J13

Regulated +15VDC

+15VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

4J13 to 5J13

Regulated -15VDC

-15VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

1J13 to 2J13

Unregulated DC

+12VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

R11 to 5J13

Low logic signal for

0 - 2 VDC

TIG Mode

 

gas/water valve

 

Arc Start Switch or

 

 

 

Amptrol must be

 

 

 

activated

 

 

 

 

R32 to 5J13

Low logic signal for

0 - 2 VDC

If input contactor is

 

interlock control

 

staying closed signal

 

 

 

will normally be low.

 

 

 

 

R13 to 5J13

Low logic signal

0 - 2 VDC

CAUTION: High

 

for high frequency

 

frequency may

 

 

 

damage test

 

 

 

equipment.

 

 

 

Use analog

 

 

 

volt/ohmmeter

 

 

 

TIG Mode

 

 

 

High frequency is

 

 

 

active after gas

 

 

 

preflow time.

 

 

 

 

R66 to 5J13

Low logic signal for

0 - 2 VDC

StickMode

 

DC OCV Boost

 

DC Mode

 

(CR3) relay

 

 

 

 

 

 

R8 to 5J13

Low logic signal for

0 - 2 VDC

Stick Mode

 

AC OCV Boost

 

AC Mode

 

(CR2) relay

 

 

 

 

 

 

SQUARE WAVE TIG 355

Page 99
Image 99
Lincoln Electric SVM118-A service manual Control PC Board Voltage Test Points Chart