Lincoln Electric SVM118-A service manual Control PC Board Voltage Test Points Chart

Models: SVM118-A

1 149
Download 149 pages 43.8 Kb
Page 99
Image 99

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-50

F-50

TROUBLESHOOTING & REPAIR

CONTROL PC BOARD TEST (continued)

CONTROL PC BOARD VOLTAGE TEST POINTS CHART

 

 

 

Special

 

 

 

 

Signals Being

Expected

Conditions

Test Points

Checked

Reading

for Test

 

 

 

 

3J13 to 5J13

Regulated +15VDC

+15VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

4J13 to 5J13

Regulated -15VDC

-15VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

1J13 to 2J13

Unregulated DC

+12VDC

None

 

supply to control

 

 

 

board

 

 

 

 

 

 

R11 to 5J13

Low logic signal for

0 - 2 VDC

TIG Mode

 

gas/water valve

 

Arc Start Switch or

 

 

 

Amptrol must be

 

 

 

activated

 

 

 

 

R32 to 5J13

Low logic signal for

0 - 2 VDC

If input contactor is

 

interlock control

 

staying closed signal

 

 

 

will normally be low.

 

 

 

 

R13 to 5J13

Low logic signal

0 - 2 VDC

CAUTION: High

 

for high frequency

 

frequency may

 

 

 

damage test

 

 

 

equipment.

 

 

 

Use analog

 

 

 

volt/ohmmeter

 

 

 

TIG Mode

 

 

 

High frequency is

 

 

 

active after gas

 

 

 

preflow time.

 

 

 

 

R66 to 5J13

Low logic signal for

0 - 2 VDC

StickMode

 

DC OCV Boost

 

DC Mode

 

(CR3) relay

 

 

 

 

 

 

R8 to 5J13

Low logic signal for

0 - 2 VDC

Stick Mode

 

AC OCV Boost

 

AC Mode

 

(CR2) relay

 

 

 

 

 

 

SQUARE WAVE TIG 355

Page 99
Image 99
Lincoln Electric SVM118-A service manual Control PC Board Voltage Test Points Chart