Lincoln Electric SVM118-A service manual Perform the Input Contactor

Models: SVM118-A

1 149
Download 149 pages 43.8 Kb
Page 54
Image 54

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-5

F-5

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

The input contactor activates

1.

Check the input voltage at the

1.

Perform the Input Contactor

 

when “start” button is pushed but

 

machine. Input voltage must

 

Test.

 

will NOT stay closed. Machine

 

match the rating plate and the

2.

Perform the Control

 

shuts off when “start” button is

 

reconnect panel.

 

 

 

Transformer Test.

 

released.

 

 

 

 

2. Blown or missing control cir-

 

 

 

 

3.

Perform the Feed – Thru PC

 

 

 

cuit fuse (F1).

 

 

 

 

Board Test.

 

 

 

 

 

 

 

 

 

4.

Perform the Control Board

 

 

 

 

 

Interlock Test.

 

 

 

 

5.

The power board may be

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

The machine shuts off and the

1.

Check the input voltage at the

1.

Perform the Control

 

control fuse (F1) repeatedly fails.

 

machine. Input voltage must

 

Transformer Test.

 

 

 

match the rating plate and the

2.

Perform the Power Board

 

 

 

reconnect panel.

 

 

 

 

Test.

 

 

 

 

 

 

 

2. Make sure the fuse is the cor-

3.

The control board may be

 

 

 

rect rating (1/2 amp).

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

3. The input voltage may be too

 

 

 

 

 

high (more than 10% over

 

 

 

 

 

rated).

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355

Page 54