Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
| TROUBLESHOOTING & REPAIR |
| |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines | |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
The input contactor activates | 1. | Check the input voltage at the | 1. | Perform the Input Contactor |
|
when “start” button is pushed but |
| machine. Input voltage must |
| Test. |
|
will NOT stay closed. Machine |
| match the rating plate and the | 2. | Perform the Control |
|
shuts off when “start” button is |
| reconnect panel. |
| ||
|
| Transformer Test. |
| ||
released. |
|
|
|
| |
2. Blown or missing control cir- |
|
|
| ||
| 3. | Perform the Feed – Thru PC |
| ||
|
| cuit fuse (F1). |
| ||
|
|
| Board Test. |
| |
|
|
|
|
| |
|
|
| 4. | Perform the Control Board |
|
|
|
|
| Interlock Test. |
|
|
|
| 5. | The power board may be |
|
|
|
|
| faulty. Replace. |
|
|
|
|
|
|
|
The machine shuts off and the | 1. | Check the input voltage at the | 1. | Perform the Control |
|
control fuse (F1) repeatedly fails. |
| machine. Input voltage must |
| Transformer Test. |
|
|
| match the rating plate and the | 2. | Perform the Power Board |
|
|
| reconnect panel. |
| ||
|
|
| Test. |
| |
|
|
|
|
| |
| 2. Make sure the fuse is the cor- | 3. | The control board may be |
| |
|
| rect rating (1/2 amp). |
| ||
|
|
| faulty. Replace. |
| |
|
|
|
|
| |
| 3. The input voltage may be too |
|
|
| |
|
| high (more than 10% over |
|
|
|
|
| rated). |
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
SQUARE WAVE TIG 355