F-16

F-16

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

TIG MODE PROBLEMS

 

 

 

The machine output is intermit-

1.

The problem may be caused

1.

The machine internal ground

 

tently lost. Gas flow and high fre-

 

by high frequency inteference.

 

connections may be loose.

 

quency are also interrupted.

 

Make sure that the machine is

 

Check the mounting screws on

 

 

 

grounded properly according

 

the protection board, the

 

 

 

to the installation instructions.

 

bypass boards, and the feed-

 

 

 

If there are other high frequen-

 

thru board.

 

 

 

cy sources in the area, make

2. The protection or bypass

 

 

 

certain they are grounded

 

 

 

 

boards may be faulty. Check

 

 

 

properly.

 

 

 

 

 

or replace.

 

 

 

 

 

 

 

2. Check the Arc Start switch or

3. Perform the Arc Start Trigger

 

 

 

Amptrol for proper operation

 

 

 

 

Circuit Test.

 

 

 

and loose connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

The arc “flutters” when TIG weld-

1.

The tungsten electrode may be

1.

Check for loose shunt connec-

 

ing.

 

too large in diameter.

 

tions, leads #222 and #221.

 

 

2. The tungsten electrode may

 

See Wiring Diagram.

 

 

 

 

 

 

 

needed sharpening.

2.

Check polarity switch for loose

 

 

3. If helium shielding gas is used,

 

or faulty connections.

 

 

 

 

 

 

 

reduce the percentaghe of heli-

3.

Perform the SCR Rectifier

 

 

 

um.

 

Bridge Tests.

 

 

4.

Adjust the gas flow rate to the

4.

Check components R6 and C6

 

 

 

proper level for the process

 

in the high voltage transformer

 

 

 

being used.

 

primary circuit. Replace if nec-

 

 

5. Check gas hoses and connec-

 

essary.

 

 

 

 

 

 

 

tions for leaks.

5.

The control board may be

 

 

 

 

 

faulty. Replace.

 

 

 

 

6. The power board may be

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355