TROUBLESHOOTING & REPAIR

TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED

DC TIG MODE

CAUTION

HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

CH1

0 volts

20 volts

2 ms

MACHINE LOADED TO 350 AMPS

AT 34VDC

This is a typical DC (+) output voltage waveform generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division rep- resents 2 milliseconds in time. The machine was loaded with a resis- tance grid bank. The TIG 355 display read 350 amps at 34 VDC.

Note: Scope probes connected at

machine output terminals: (+) probe to electrode terminal, (-) probe to work terminal.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

2 ms/Div.

Coupling

DC

Trigger

Internal

 

 

SQUARE WAVE TIG 355