F-42

F-42

TROUBLESHOOTING & REPAIR

MAIN TRANSFORMER TEST (continued)

FIGURE F.12 - MAIN TRANSFORMER LOCATION AND WIRING DETAILS

X5 X6

X1

 

X7

X2

X3

 

 

X4

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the machine.

2.With the 5/16" nut driver, remove the machine top and sides.

3.Perform the power factor capacitor dis- charge procedure.

4.Inspect the input contactor, reconnect panel, and primary leads to the main trans- former for loose or faulty connections.

5.Check the reconnect panel to make sure that the single phase AC power supplied to the machine is properly connected.

6.Locate leads X1 though X7. See Figure F.12.

WARNING

ELECTRIC SHOCK can kill.

With input power ON, there are high volt- ages inside the machine. Do not reach into the machine or touch any inter- nal part of the machine while power is on.

7. Turn on input power to the machine.