F-4

F-4

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Major physical or electrical dam-

1.

Contact your local authorized

1.

Contact the Lincoln Electric

age is evident when the sheet

 

Lincoln Electric Field Service

 

Service Department, 216-383-

metal cover(s) are removed.

 

Facility for technical assis-

 

2531 or 1-800-833-9353

 

 

tance.

 

(WELD).

 

 

 

 

 

Machine is dead – no output – no

1.

Check the input voltage at the

1.

If when the “start” button is

fans – no displays.

 

machine. Input voltage must

 

pushed the pilot light is lit and

 

 

match the rating plate and the

 

the input contactor (CR1) acti-

 

 

reconnect panel.

 

vates, check the wiring at the

 

2. Check for blown or missing

 

reconnect panel and also to

 

 

the main transformer primary

 

 

fuses in the input lines.

 

 

 

 

coils.

 

 

 

 

 

3. Check for a blown or missing

2. Perform the Input Contactor

 

 

control circuit fuse F1.

 

 

 

Test.

 

 

 

 

 

4.

The machine secondary

3. Perform the Main Transformer

 

 

thermostat may be open.

 

 

 

Test.

 

 

Allow machine to cool.

 

 

 

 

 

 

 

 

4. If when the “start” button is

 

 

 

 

pushed the pilot light does

 

 

 

 

NOT light and the input con-

 

 

 

 

tactor does NOT activate,

 

 

 

 

check the start/stop button for

 

 

 

 

proper operation.

 

 

 

5. Perform the Pilot Transformer

 

 

 

 

Test.

 

 

 

6. If when the “start” button is

 

 

 

 

pushed the pilot light is lit and

 

 

 

 

the input contactor does NOT

 

 

 

 

activate, perform the Input

 

 

 

 

Contactor Test.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355