F-9

F-9

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

1. In Stick mode the machine

1.

If the machine is in the Remote

1.

If the machine works properly

welds at a very low output,

 

control mode, make sure a

 

in Local control mode but not

regardless of the peak current

 

Lincoln remote control device

 

in Remote mode, perform the

control setting.

 

is connected to the amphenol.

 

Protection Board Test.

 

2.

The Start Current may be set

2.

If the machine operates prop-

 

 

too low for the electrode size

 

erly in TIG mode but not in

 

 

being used.

 

Stick mode, the control board

 

3. If the machine works properly

 

may be faulty. Replace.

 

 

 

 

 

in Local control mode, check

3.

If the output is low in all

 

 

or replace the remote control

 

modes, perform the SCR

 

 

device.

 

Bridge Test.

 

4.

If the machine works properly

4.

The power board may be

 

 

in TIG mode, contact your

 

faulty. Replace.

 

 

local authorized Lincoln

5.

The control board may be

 

 

Electric Field Service Facility.

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355