TROUBLESHOOTING & REPAIR
CONTROL TRANSFORMER (T5) VOLTAGE TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call
TEST DESCRIPTION
The following procedure will determine if the correct voltage is being applied to the primary of the control transformer and induced on the secondary.
MATERIALS NEEDED
Volt/Ohmmeter (Multimeter) 5/16” Nut Driver
Machine Wiring Diagrams (See the Electrical Diagram Section of this manual.)
Control Transformer (T5) Voltage Test Chart and drawing of transformer and molex plug (P4), Figure F.14.
SQUARE WAVE TIG 355