F-7

F-7

 

TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

The machine shuts off (pilot light

1. The input voltage may be too

1.

Perform the SCR Bridge Test.

goes out and the fans stop) when

high (more than 10% over

2.

Perform the Power Board

the Arc Start Switch or Amptrol is

rated).

 

Test.

activated.

 

 

2. The Arc Start switch may be

 

 

 

3.

Perform the Control Board

 

faulty. Check or replace.

 

 

Test.

 

 

 

 

 

4.

Shunt may be faulty or over-

 

 

 

heated. Check for loose con-

 

 

 

nections and replace shunt if

 

 

 

necessary.

The 115VAC receptacle does not

1.

The circuit breaker CB1 may

1.

The circuit breaker may be

work. The machine operates nor-

 

have opened. Reset if neces-

 

faulty. Test or replace.

mally.

 

sary.

2.

If the fans are running, check

 

 

 

 

2.

Check for the presence of

 

the receptacle and the associ-

 

 

115VAC at the receptacle.

 

ated wiring.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355

Page 56