
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
AC STICK MODE
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
•Perform all voltage and waveform checks with high frequency circuit OFF.
CH1
0 volts
50 volts | 2 ms |
This is the typical AC output voltage waveform generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe to electrode terminal,
SCOPE SETTINGS
Volts/Div | 50V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|
SQUARE WAVE TIG 355