TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Fans and display are functional.

1. The primary thermostat may be

1.

If the machine works properly

No output from machine in either

open. Allow machine to cool.

 

in Local control mode but not

Stick or TIG modes.

2. If the machine is in Remote

 

in Remote control, then per-

 

 

form the Protection Board

 

control mode, make sure a

 

 

 

Test.

 

Lincoln remote control device

 

 

 

 

 

is connected to the amphenol.

2.

If the machine does NOT have

 

3. If the machine works properly

 

output in either mode, Local or

 

 

Remote, check the primary

 

in the Local control mode,

 

 

 

thermostat for proper opera-

 

check or replace the remote

 

 

 

tion. It is normally closed.

 

control device.

 

 

 

 

 

 

3.

Perform the Arc Start Trigger

 

 

 

Circuit Test.

 

 

4.

Perform the SCR Bridge Test.

 

 

5.

Perform the Control

 

 

 

Transformer Test.

 

 

6.

Perform the Power Board

 

 

 

Test.

 

 

7.

The control board may be

 

 

 

faulty. Replace.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

SQUARE WAVE TIG 355

Page 55
Image 55
Lincoln Electric SVM118-A service manual Form the Protection Board