Lincoln Electric SVM118-A Output Current Range, Recommended Meters for Machine Output Tests

Models: SVM118-A

1 149
Download 149 pages 43.8 Kb
Page 134
Image 134

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-85

F-85

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR (continued)

OUTPUT CURRENT RANGE

2 - 400 Amps AC and DC

RECOMMENDED METERS FOR MACHINE OUTPUT TESTS

VOLTMETER:

AC and DC True RMS Meter – Fluke 8922A or equivalent

AMMETER:

Columbia Type AX AC or DC Tong Ammeter

IMPORTANT: IF OTHER TYPE METERS ARE USED RESULTS MAY NOT BE ACCURATE

FIGURE F32. – TRANSFORMER LEAD TEST POINTS

X5 X6

X1

X7

X2

X3

X4

MAIN TRANSFORMER SECONDARY VOLTAGES (SEE FIGURE F32)

Test Points

 

Voltages

 

 

 

X1 to X2

 

84 to 89VAC

X3 to X4

 

117 to 125VAC

X5 to X6

 

22 to 24VAC

X2 to X7

 

77 to 81VAC

 

 

 

 

SQUARE WAVE TIG 355

Page 134
Image 134
Lincoln Electric SVM118-A Output Current Range, Recommended Meters for Machine Output Tests, Test Points Voltages