Lincoln Electric SVM118-A service manual Control Transformer T5 Voltage Test

Models: SVM118-A

1 149
Download 149 pages 43.8 Kb
Page 94
Image 94

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-45

F-45

TROUBLESHOOTING & REPAIR

CONTROL TRANSFORMER (T5) VOLTAGE TEST (continued)

FIGURE F.13 - LOCATION OF CONTROL BOARD AND CONTROL TRANSFORMER

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Remove input power to the machine.

2.With the 5/16” nut driver, remove the machine case top and sides.

3.Locate plug J4 on the power board. (Do not remove.) Also locate the two black sec- ondary leads. See Figure F.13.

WARNING

ELECTRIC SHOCK can kill.

With input power ON, there are high voltages inside the machine. Do not reach into the machine or touch any internal part of the machine while power is on.

4.Check for 120VAC at the primary leads #265 to #266.

A.If 120VAC is present at leads #265 to #266, go to Step 7.

Note: If input voltage varies, the con- trol transformer voltages will vary accordingly.

B.If a very low or zero voltage is shown at leads #265 to #266, go to Step 5.

5.Remove input power to machine.

Return to Section TOC

Return to Master TOC

3. Turn input power ON.

SQUARE WAVE TIG 355

Page 94
Image 94
Lincoln Electric SVM118-A service manual Control Transformer T5 Voltage Test