Removing the overheat thermostat

1.Disconnect the overheat thermostat electrical connections “N1” (FIG. 1.54);

2.Then remove the thermostat from its mounting by releasing the securing clip (FIG. 1.55).

N1

80.eps

FIG. 1.54

 

 

83.eps

FIG. 1.55

Removing the D.H.W. temperature sensor (N.T.C.)

1.Pull off the electrical connector “Q1” and unscrew the sensor probe using a suitable spanner (FIG. 1.57).

 

Q1

60.eps

FIG. 1.57

Removing the divertor valve actuator

1.Unplug the electrical connector “R1” (FIG. 1.58);

2.Release the retaining clip “S1” and remove the divertor valve actuator.

R1

S1

74.eps

FIG. 1.58

Removing the heating temperature sensor (N.T.C.)

1.Pull off the electrical connector “P1” and unscrew the sensor probe using a suitable spanner (FIG. 1.56).

 

 

 

 

 

 

P1

 

 

 

 

 

 

FIG. 1.56

87.eps

 

 

 

 

 

Removing the D.H.W. flow switch

1.Unplug the electrical connector “T1” (FIG. 1.59);

2.Release the retaining clip “V1” and remove the D.H.W. flow switch.

V1

30.eps

T1

FIG. 1.59

B063