C

 

 

 

 

IS THE

NO

 

 

 

AIR PRESSURE SWITCH

 

 

 

ACTIVATED?

 

 

 

 

YES

CHECK

P

1.2 mbar 1 - Check A.P. switch cable

P ON TEST

 

PRESSURE

 

 

2 - Check/replace A.P. switch

 

 

 

3 - Check/replace P.C.B.

 

INTAKE

 

 

 

 

 

 

 

 

 

1 - Check exhaust discharge

 

P 1.2 mbar

 

2 - Check venturi & pipes

 

 

 

 

 

 

 

 

3 - Check fan efficiency

 

 

 

 

1 - Check/replace ignition

IS FLUE

 

 

 

electrode

NO

 

 

2 - Check ignition cable

DISCHARGE

 

 

 

 

3 - Check spark generator

NORMAL?

 

 

 

 

 

 

4 - Check ignition electrode

 

 

 

 

 

 

 

 

cable

YES

 

 

 

5 - Check/replace P.C.B.

 

 

 

 

 

 

 

 

1 - Check power supply of

 

 

 

 

gas valve

IS THE BURNER

NO

 

 

2 - Check/replace P.C.B.

 

 

3 - Check efficiency of

ALIGHT?

 

 

 

 

 

 

 

gas valve

YES

 

 

 

4 - Replace gas valve

 

 

 

 

HAS THE

 

 

 

1 - Check if flame strikes

 

 

 

detection electrode

BOILER SAFETY

YES

 

 

2 - Check soft-light gas

SHUTDOWN BEEN

 

 

pressure

ACTIVATED?

 

 

 

3 - Check/replace detection

 

 

 

 

electrode

NO

 

 

 

4 - Check/replace P.C.B.

 

 

 

 

D

 

 

 

HAS THE

 

NO

BOILER SAFETY

 

SHUTDOWN BEEN

 

 

 

 

ACTIVATED?

 

 

 

 

YES

 

 

 

 

Shutdown L.E.D. off

 

 

 

 

fan restarts

 

 

 

 

FC004Ad

B063

 

 

 

21

Page 45
Image 45
Ariston 47-116-15 installation instructions ∆ P 1.2 mbar