61.eps

Soft-light

Max Heating

Adjustment

Adjustment

VR015A.eps

Removing the spark generator

1.Disconnect ignition leads “T” by pulling upward (FIG. 1.27);

2.Remove the screw “V” (FIG. 1.28);

3.Remove the spark generator (FIG. 1.29).

T

45.eps

FIG. 1.27

10.Remove the pipe from the pressure gauge and connect screw “C” to the pressure outlet in order to seal off the

gas.

11. Carefully check the pressure outlets for gas leaks (valve inlet and outlet).

IMPORTANT!

Whenever you disassemble and reassemble the gas connections, always check for leaks using a soap and water solution.

V

43.eps

FIG. 1.28

 

 

 

 

 

44.eps

FIG. 1.29

 

10

 

 

B063

Page 34
Image 34
Ariston 47-116-15 installation instructions Removing the spark generator