61.eps
Max Heating | |
Adjustment | Adjustment |
VR015A.eps
Removing the spark generator
1.Disconnect ignition leads “T” by pulling upward (FIG. 1.27);
2.Remove the screw “V” (FIG. 1.28);
3.Remove the spark generator (FIG. 1.29).
T
45.eps | FIG. 1.27 |
10.Remove the pipe from the pressure gauge and connect screw “C” to the pressure outlet in order to seal off the
gas.
11. Carefully check the pressure outlets for gas leaks (valve inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas connections, always check for leaks using a soap and water solution.
V
43.eps | FIG. 1.28 |
|
|
|
|
| 44.eps | FIG. 1.29 |
|
10 |
|
| B063 |