7.TECHNICAL INFORMATION

CE Certification

 

 

 

Heat Input

 

max/min

kW

Heat Output

 

max/min

kW

Efficiency of Nominal Heat Input

%

 

Efficiency at 30% of Nominal Heat Input

%

 

Heat Loss to the Casing (T=50°C)

%

 

Flue Heat Loss with Burner Operating

%

 

Flue Heat Loss with Burner Off

%

 

Maximum Discharge of Fumes (G20)

Kg/h

 

Residual Discharge Head

mbar

 

Consumption at Nominal Capacity(G20)

m3/h

 

Gas Consumption after 10 Minutes*

m3

 

(15°C, 1013 mbar) (G30-G31)

Kg/h

 

Temp. of exhaust fumes at nominal capacity

°C

 

CO2 Content

 

%

 

O2 Content

 

%

 

CO Content

 

ppm

 

Minimum Ambient Temperature

°C

 

Head Loss on Water Side (max) (T=20°C)

mbar

 

Residual Head of System

 

bar

 

Heating Temperature

 

max/min °C

Domestic Hot Water Temperature

max/min °C

D.H.W. Flow Rate T=35°C

l/min

 

D.H.W. Flow Rate T=35°C

gal/min

 

D.H.W. Minimum Flow Rate

l/min

 

Pressure of Domestic Hot Water

max/min bar

Expansion Vessel Capacity

l

 

Expansion Vessel Pre-load Pressure

bar

 

Maximum Water Content of System

l

 

Maximum Heating Pressure

bar

 

Nominal Pressure

Natural Gas (G20)

mbar

 

 

LPG (G30-G31)

mbar

 

Electrical Supply

 

V/Hz

 

Power Consumption

 

W

 

Protection Grade of Electrical System

IP

 

Internal Fuse Rating

 

 

 

Weight

 

Kg

 

23 MFFI

63AU4549

25.6/11.0

92.9

91.1

1.0

6.1

0.4

49.5

0.96

2.72

0.32/0.39

2.02/2.00

123

7.2

7.5

51.9

+5

200

0.25

82/42

56/36

9.7

2.2

2.6

8/0.2

6

1

130

3

20

30-37

230 / 50

140

X4D

FAST 2 AT

38

27 MFFI

63AU4549

29.8/12.0

93.5

90.7

0.2

6.3

0.4

60

1.60

3.15

0.37

2.34/2.31

128.8

6.9

8.1

48

+5

200

0.25

82/42

56/36

11.4

2.6

2.6

8/0.2

6

1

130

3

20

30-37

230 / 50

155

X4D

FAST 2 AT

39

G.C. Number

47-116-14

47-116-15

*Calculated at 70% maximum output

Manufacturer: Merloni TermoSanitari SpA - Italy

Commercial subsidiary: MTS (GB) LIMITED MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone: (01494) 755600 Fax: (01494) 459775

internet: http://www.mtsgb.ltd.uk

E-mail: info@mtsgb.ltd.uk

Technical Service Hot Line: (01494) 539579

23 99 84 1469 312 - Stampa: bieffe RECANATI