4.GAS ADJUSTMENTS

CATEGORY II2H3+

 

Methane Gas

Liquid Butane Gas

Liquid Propane Gas

 

 

G20

G30

G31

 

 

 

 

 

Lower Wobbe Index (15°C;1013mbar)

MJ/m3h

45.67

80.58

80.58

Nominal Delivery Pressure

mbar

20

29

37

Minimum Delivery Pressure

mbar

17

20

25

23 MFFI

 

 

 

 

Main Burner: n. 13 jets (ø )

mm

1.30

0.77

0.77

Consumption (15°C; 1013mbar)

mc/h

2.72

----

----

Consumption (15°C; 1013mbar)

Kg/h

----

2.02

2.02

Gas Cock Outlet Pressure

 

 

 

 

max - min

mbar

11.0 - 2.0

(*) - 6.0

(*) - 6.0

27 MFFI

 

 

 

 

Main Burner: n. 15 jets (ø )

 

1.30

0.77

0.77

Consumption (15°C; 1013mbar)

mc/h

3.15

----

----

Consumption (15°C; 1013mbar)

Kg/h

----

2.34

2.31

Gas Cock Outlet Pressure:

 

 

 

 

max - min

mbar

11.0 - 1.6

(*) - 4.6

(*) - 6.0

 

 

 

 

 

[1 mbar = 10,197 mmc.a.]

4.1CHANGING THE TYPE OF GAS

The outlet pressure of the gas cock is obtained by completely loosening the screw on the solenoid. The maximum pressure of the gas to the burner will be equal to the nominal delivery pressure minus the head loss within the gas valve.

The boiler can be converted to use either methane (natural) gas (G20) or LPG (G30 - G31) by an Authorised Service Centre.

The operations that must be performed are the following:

1.Replace the jets on the main burner (see table in section 4);

2.Adjust the maximum and minimum thermal capacity values for the boiler (see table in section 4);

3.Replace the gas rating plate;

4.Adjust the maximum thermal power setting;

5.Adjust the soft-light feature;

6.Adjust the ignition delay feature for the heating system (can be set from 0 to 2 mins.).

CATEGORY II2H3+

Methane

Liquid

Liquid

 

Gas

Butane

Propane

 

G20

Gas

Gas

 

 

G30

G31

Recommended Soft-

 

 

 

light Pressure

8.0

16.0

16.0

(mbar)

 

 

 

 

 

 

 

20

Page 20
Image 20
Ariston 47-116-15 installation instructions GAS Adjustments, Methane Liquid Gas Butane, G20 Gas G30, 16.0