Starting a New Job (or Refilling the Cup)
Starting a New Job
(or Refilling the Cup)
When spraying flammable or combustible materials:
•Remove entire sprayer from hazardous location when refilling.
•Always ground the material cup when refilling.
•Keep material containers covered between cup refills.
1.Engage trigger lock and put prime/pressure relief valve UP to release pressure.
ti16700a
ti16699a
2.Install material cup liner, fill with material, and thread onto sprayer.
ti16715a
3.To prime pump, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/relief valve DOWN to spray position.
4.Reverse spray tip to UNCLOG position and spray into waste area for five seconds.
ti14991a
ti16713a
5.Put prime/pressure relief valve UP to release pres- sure. Then rotate tip back to spray position. NOTE: Failure to perform this operation could result in poor spray pattern.
ti16700a
ti16992a
NOTE: If sprayer fails to prime, follow Alternate Priming Method (page 23).
Reversible Tip Selection Chart
Fine Finish Materials and Tip Sizes
Fan | THIN | MEDIUM | HEAVY | |
Width | Stains | Lacquers, Clears | Enamels | |
|
|
|
| |
4 in. | 208 | 210 |
| |
(10 cm) |
| |||
|
|
| ||
|
|
|
| |
6 in. | 308 | 310 | 312 | |
(15 cm) | ||||
|
|
| ||
|
|
|
| |
8 in. |
| 410 | 412 | |
(20 cm) |
| |||
|
|
| ||
|
|
|
|
Use with all fine finish materials including “hot” solvents.
ti16698a
ti16716ati16701a
3A1698F | 13 |