Graco 16H243, 262612, 16H241, 16H245, 16H242, 16F887 16H240 Shutdown and Cleaning, Flushing Sprayer

Models: 16H829 16H242 262612

1 32
Download 32 pages 47.92 Kb
Page 16
Image 16
Shutdown and Cleaning

Shutdown and Cleaning

NOTICE

Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the warranty will no longer be valid. Do not store solvents other than mineral spirits in sprayer. Always flush with Graco pump armor prior to storage.

Flushing Sprayer

Do not spray solvents through the spray tip. Clean the tip in a bucket of compatible solvent.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

NOTICE

Protect the internal parts of this sprayer from water.

Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electron- ics inside. If water or cleaning fluid gets into these open- ings, the sprayer could malfunction or become permanently damaged.

1.Engage trigger lock and pull prime/pressure relief valve UP to release pressure.

ti16699a

ti16700a

2.Remove material cup and return excess material to proper container. If used, properly dispose the cup liner.

ti16724a

Shutdown and Cleaning

3.Remove and clean sprayer intake tube and screen with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect intake tube.

ti16725a

4.Clean cup if not using a liner, and fill with water or appropriate flushing fluid.

ti16726a

5.Reconnect material cup and shake sprayer to move clean water around and clean all areas inside of cup.

ti16723a

6.Disconnect trigger lock and trigger sprayer for approximately 15 seconds. Engage trigger lock.

ti16993ati16716a

7.Discard contaminated fluid and refill with appropri- ate flushing fluid.

16

3A1698F

Page 16
Image 16
Graco 16H243, 262612, 16H241 Shutdown and Cleaning, Flushing Sprayer, Protect the internal parts of this sprayer from water