Alternate Priming Method

Alternate Priming Method

Move sprayer to a non-hazardous area before servicing.

If sprayer fails to prime, the inlet valve may be stuck due to paint residue. Perform the steps below.

1.Engage trigger lock and pull prime/pressure relief valve UP to release pressure.

5.Leaving the sprayer upside-down, disengage trigger lock and quickly trigger sprayer until material comes out of drain port.

ti16698ati16997a

6.Install strainer on suction tube and thread material cup back onto sprayer.

ti16699a

ti16700a

ti14994a

ti14999a

2. Remove material cup and suction tube.

ti16746a

3.Use a pencil or thin rod to lightly push on inlet valve to make sure it moves up and down freely.

ti16712a

7.Trigger gun for 10 seconds then release trigger and put prime/pressure relief valve DOWN to spray posi- tion.

ti16716a

ti16701a

8.Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.

ti16753a

4.If inlet valve does not move freely, perform Inlet Valve Removal, page 24. If inlet valve moves freely, install suction tube without strainer, turn sprayer upside-down, and slowly pour flushing material into suction tube until full.

ti16996a

ti14991a

ti16713a

9.Pull prime/pressure relief valve up to release pres- sure, reverse spray tip to SPRAY position and put prime/pressure relief valve DOWN to spray position. Sprayer is now ready to spray. Perform Starting New Job procedure, page 13.

3A1698F

23

Page 23
Image 23
Graco 16H243, 262612, 16H241, 16H245, 16H242, 16F887  16H240, 16H829 important safety instructions Alternate Priming Method