Shutdown and Cleaning
8.Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer.
11.Engage trigger lock and put prime/pressure relief valve UP to release pressure.
ti16698a ti14991a
ti16699a
ti16700a
ti14999a
9.Put prime/pressure relief valve DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.
ti16701a
ti16713a
10. If sprayer is not completely clean, repeat steps
To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.
ti15529ati16727a
Keep spray area
12.Remove material cup and discard used fluid.
13.Use a stiff wire such as a paper clip to make sure vent hole is open.
ti17102a
14.Remove Spray Tip/Guard Assembly and clean with water or flushing fluid. A soft brush can be used to loosen and remove dried material if needed.
ti15003a
ti15003a
NOTICE
The tip is permanently attached to the guard. Removing the tip from the guard will result in damage to the tip assembly.
Do not store tip/guard assembly or suction tube in sol- vent other than mineral spirits. Damage to parts may occur.