ACCESSORIES

 

Magic-Pak: HW/HWC

7-16

 

 

BTU/HR

=

Cubic Feet Per Revolution x 3600 x Heating

 

 

 

 

 

INPUT

 

# Seconds Per Revolution

Value

The heating value of your gas can be obtained from your local utility.

With proper manifold pressure achieved, cycle main burners on and off. Ignition and extinction should be smooth and quiet. Burning back at the orifice or flame popping back to the orifice can be corrected by adjusting the air shutter to soften the flame.

Regulator - Propane

The furnace has a regulator in the gas valve. A regulator is also required on the propane tank. Another regulator may be required at the house or the unit.

The minimum permissible gas supply pressure to the furnace is 11" W.C. for the purpose of input adjustment.

If at any time ignition is slow and the burner does not seem to be operat- ing correctly, check manifold pressure. It should be between 10" to 10.5" W.C.

The furnace is designed to obtain rated input at 10.0" W.C.

To check this pressure:

1.Turn off the gas valve.

2.Remove the plug on the valve.

3.Install a water manometer.

Turn gas valve “ON”. If manifold pressure must be adjusted, remove cap from pressure regulator and turn adjustment screw clockwise to increase pressure, counterclockwise to reduce pressure. After checking pressure, turn gas off, remove the manometer fitting and replace the pipe plug and regulator cap. Put furnace in operation and leak check plug for leaks using a soapy solution.

With proper manifold pressure achieved, cycle main burners on and off. Ignition and extinction should be smooth and quiet. Burning back at the orifice or flame popping back to the orifice can be corrected by adjusting the air shutter to soften the flame.

TABLE 7-8

AHALT390-1 Orifices

 

 

 

 

 

 

 

 

 

 

 

Normal

High

High

Orifice Size

 

Model

Altitude

Altitude

 

Input

 

 

 

Size

Input

Output

 

 

 

Btuh

Natural

Propane

 

 

Btuh

Btuh

 

 

 

 

 

 

 

 

 

 

 

26HW/HWC

26,000

23,400

18,000

55

65

 

 

 

 

 

 

 

 

38HW/HWC

38,000

24,200

27,000

54

64

 

 

 

 

 

 

 

 

51HW/HWC

51,000

45,900

36,000

54

63

SRM-

 

 

 

 

 

 

64HW/HWC

64,000

57,600

45,000

53

63

HW/HWC

 

 

 

 

 

 

 

 

 

 

 

 

8/99

Page 138
Image 138