Service Reference Manual

SPECIFICATIONS

1-3

Summary of Model Revisions/Variations

Table 1-1 Heating Configurations of HW/HWC Units

Model

Configuration

AFUE

Ignition/Blower Control

Ignition

Type

 

 

 

 

 

 

 

 

 

(All) HWC (123, 183, 243, 303) -1

Gas Heat/

80

UTech Combination Ignition/Blower Control 1097

DSI

Electric Cool

 

 

 

 

 

 

 

 

 

(All) HW -9

Gas Heat Only

80

UTech Combination Ignition/Blower Control 1097

DSI

 

 

 

 

 

(All) HWC (122, 182, 242, 302)

Gas Heat/

 

Ignition Control: Fenwal Triton 2461D

 

80

Blower Control: Heatcraft IBCH4C401,

DSI

-11, -10, -9, -8, -7, -6, -5

Electric Cool

 

Tridelta 920B0048 or UTech 1010

 

 

 

 

 

 

 

 

 

 

(All) HWC (122, 182, 242, 302)

Gas Heat/

 

Ignition Control: Fenwal 05-29

 

80

Blower Control: Heatcraft IBCH4C401,

DSI

-4, -3, -2, -1

Electric Cool

 

Tridelta 920B0048 or UTech 1010

 

 

 

 

 

 

 

 

 

 

Table 1-2 Cooling Configurations of HWC Units

Model

Configuration

Tonnage

SEER

Compressor Type*

Metering Device

 

 

 

 

 

 

(All) HWC 123-1

Gas Heat/Electric Cool

1

9.7

Tecumseh Rotary

Capillary Tube/Filter Drier

 

 

 

 

 

 

(All) HWC183-1

Gas Heat/Electric Cool

1.5

9.7

Tecumseh

Capillary Tube/Filter Drier

Reciprocating

 

 

 

 

 

 

 

 

 

 

 

(All) HWC 243-1

Gas Heat/Electric Cool

2

9.7

Copeland Scroll

Capillary Tube/Filter Drier

 

 

 

 

 

 

(All) HWC 303-1

Gas HeatElectric Cool

2.5

9.7

Copeland Scroll

Capillary Tube/Filter Drier

 

 

 

 

 

 

(All) HWC 182-11, -

Gas Heat/Electric Cool

1.5

9.7

Tecumseh

Capillary Tube/Filter Drier

9, -7, -6

Reciprocating

 

 

 

 

 

 

 

 

 

 

(All) HWC 242-11, -9

Gas Heat/Electric Cool

2

9.7

Copeland Scroll

Capillary Tube/Filter Drier

 

 

 

 

 

 

(All) HWC 122-10, -

Gas Heat/Electric Cool

1

9.7

Tecumseh Rotary

Capillary Tube/Filter Drier

8, -5, -4, -3, -1

 

 

 

 

 

 

 

 

 

 

 

(All) HWC 242-10, -

Gas Heat/Electric Cool

2

9.7

Copeland Scroll

Capillary Tube/Filter Drier

8, -5, -4, -3, -1

 

 

 

 

 

 

 

 

 

 

 

(All) HWC 302-9

Gas Heat/Electric Cool

2.5

9.5

Copeland Scroll

Capillary Tube/Filter Drier

 

 

 

 

 

 

(All) HWC 182-8, -5,

Gas Heat/Electric Cool

1.5

9.7

Tecumseh Rotary

Capillary Tube/Filter Drier

-4, -3, -2

 

 

 

 

 

 

 

 

 

 

 

(All) HWC 302-8, -5,

Gas Heat/Electric Cool

2.5

9.5

Copeland Scroll

Capillary Tube/Filter Drier

-4, -3, -1

 

 

 

 

 

 

 

 

 

 

 

(All) HWC 182-1

Gas Heat/Electric Cool

1.5

9.5

Copeland Scroll

Capillary Tube/Filter Drier

 

 

 

 

 

 

* For more information on the compressors used in HWC units, see the Unit Components section, beginning on page 5-28.

SRM-HW/HWC 8/99

Page 6
Image 6