UNIT COMPONENTS

Magic-Pak: HW/HWC

5-12

Diagnostics (United Technologies 1097-400-1)

The following blower/ignition control board LED codes indicate normal or abnormal operations:

TABLE 5-2

UTech Model 1097 Diagnostic Flash Code

 

 

SLOW FLASH

Normal Operation, No Call for Heat

 

 

FAST FLASH

Normal Operation, Call for Heat

 

 

 

2 FLASH

 

System Lockout - Failed to Detect or Sustain Flame

 

 

 

3 FLASH

 

Pressure Switch Open or Closed

 

 

 

4 FLASH

 

High Limit or Rollout Switch Open

 

 

 

5 FLASH

 

Flame Sensed and Gas Valve Not Energized

 

 

 

STEADY

 

Internal Failure (Micro-controller Failure; Self-check)

 

 

 

United Technologies Model 1097-400-1 (cont.)

Quick Connect Terminal Descriptions

124VAC HOT - from Transformer

2GROUND = 24VAC Return

4CMB BLWR = Combustion Blower (Line Voltage)

5L1 = Line Voltage

9ACB COOL = Air Circulating Blower Cool Speed (Line Voltage)

10ACB HEAT = Air Circulating Blower Heat Speed (Line Voltage)

11UNUSED (Park)

12FLAME = Flame Probe

Molex/Amp Plug-in Description

1Roll-out Switch Return

2Hi Limit Return/Pressure Switch Out

3Gas Valve Common

4Gas Valve Out

5Pressure Switch Return

6Roll-out Switch Out

Thermostat Input

R

24VAC to Thermostat (RED)

G

Manual Fan Input from Thermostat (GREEN)

W

Heat Demand Input from Thermostat (WHITE)

C

Common Ground to Thermostat

Y

SRM-HW/HWC

Cool Demand Input from Thermostat (YELLOW)

2/99

Page 75
Image 75
Armstrong World Industries 122, 243, 302, 242, 123, 203, 182, 183 manual United Technologies Model 1097-400-1