Technical Specifications
RS232 Connections
Technical Specifications
Physical Dimensions:
17” x 0.9” x 12”
Weight:
Approximately 2 lbs. (2.73 kg)
Flash EEPROM and EEPROM
Environmental Conditions:
Operating Temperature: 0° to 40° C ambient
Operating Humidity: 5 to 85% noncondensing
Operating Altitude: 10,000 ft. (3,048 m) maximum
Storage Temperature: 
Storage Humidity: 5 to 90% noncondensing
Storage Altitude: 25,000 ft. (7,620 m) maximum
Warranty:
1 year
Table 5 lists the pin assignments for a standard RS232 connector.
| Table 5 | RS232 Connector Pin Assignments | ||
| 
 | Pin | 
 | Function | 
| 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
| 
 | 1 | 
 | Protective ground | 
| 
 | 2 | 
 | Transmit data | 
| 
 | 3 | 
 | Receive data | 
| 
 | 4 | 
 | Request to send | 
| 
 | 5 | 
 | Clear to send | 
| 
 | 6 | 
 | Data set ready | 
| 
 | 7 | 
 | Signal ground | 
| 
 | 8 | 
 | Carrier detect | 
| 
 | 20 | 
 | Data terminal ready | 
| 
 | 22 | 
 | Ring indicator | 
| 
 | 
 | 
 | 
 | 
Cable Limitations for The AMS link can not be more than 2000 feet between first and 
chain.
Page 41