7.A confirmation screen appears.

Press <M> to keep existing data on the first disk. If you choose this option, data on the first disk will be mirrored on the second disk that you will add to the volume later. Make sure the data you want to mirror is on the first disk. Press <D> to overwrite any data and create the new IM array.

LSI Corp Config Utility

v6.20.00.00 (2007.12.04)

Create New Array -- SAS1064E

 

M- Keep existing data, migrate to an IM array. Synchronization of disk will occur.

D- Overwrite existing data, create a new IM array. ALL DATA on ALL disk in the array will be DELETED!!

No Synchronization performed.

Esc = Exit Menu

F1/Shift+1 =

Help

Space/+/- = Select disk for array

or hot spare C = Create array

 

 

 

8.Repeat steps 5 and 6 to add the second disk to the volume.

9.When done, press <C> to create the array, then select Save changes then exit this menu.

Create and save new array?

Cancel Exit

Save changes then exit this menu

Discard changes then exit this menu

Exit the Configuration Utility and Reboot

10. The utility creates the array.

LSI Corp Config Utility

v6.20.00.00 (2007.12.04)

 

 

Processing...may take up to 1 minute

Creating RAID array...

6-46

Chapter 6: RAID configuration