Chapter 4. Administrator Utility

Upgrade Failed

If a device fails to complete the upgrade successfully, start the firmware upgrade procedure again. If the KM0832 becomes inoperable after a failed firmware upgrade, follow the procedure to recover from a failed firmware upgrade.

Recovering from a Failed Firmware Upgrade

If a firmware upgrade procedure is aborted prematurely (due to a power outage, for example), the KVM switch that was being upgraded at the time may become inoperable and may be incapable of accepting a normal firmware upgrade. Follow this procedure to recover from the failed firmware upgrade.

To recover from a failed firmware upgrade:

1.Power off the first-level KM0832. Do not power off the cascaded and daisy-chained KVM switches (if applicable).

2.Locate the F/W UPGRADE switch on the back panel of the KM0832. Slide the switch to the RECOVER position.

3.Power on the first-level KM0832.

4.Upgrade the firmware using the Firmware Upgrade Utility.

(See Upgrading Firmware via the Firmware Upgrade Utility, page 85.)

5.When the firmware upgrade recovery completes, the KM0832 will issue a single continuous beep.

6.Slide the F/W UPGRADE switch to the NORMAL position. The beep will stop.

7.Power off the first-level KM0832, wait 5 seconds, and then power it on again.

8.Upgrade the firmware to the latest firmware version. (See Upgrading Firmware via the KM0832 Administrator Utility, page 83.) If you already upgraded to the latest firmware version in Step 4, you do not need to upgrade the firmware again.