PN0108 User Manual

(Continued from previous page.)

No.

Item

Description

 

 

 

3

Power

Each button (A to H), controls the power status of its

 

Control

corresponding AC output port as follows:

 

Buttons

Š Pressing the button for less than 3 seconds toggles the port

 

 

 

 

between Remote Access enabled and Remote Access disabled

 

 

(Local Mode). If Remote Access is disabled, the switch does not

 

 

allow the port to be managed from a remote connection. (The

 

 

Remote Access LED is off when Remote Access Mode has

 

 

been disabled for its corresponding port.)

 

 

Š Under Local Mode, pressing and holding the button in for more

 

 

than 3 seconds switches the power to its corresponding port On

 

 

or Off.

 

 

 

4

Reset

Pressing and holding this switch in for more that three seconds

 

Switch

resets the PN9108 to its factory default settings. This switch is

 

 

recessed and must be pushed with a thin object, such as the end

 

 

of a paper clip, or a ballpoint pen.

 

 

 

5

Station ID

The PN0108's Station ID displays here. If this is a Single Station

 

LED

installation (See Single Stage Installation, page 11, or the First

 

 

Station on a Daisy Chained installation (see Daisy Chaining,

 

 

page 13), the PN0108 has a Station ID of 01.

 

 

 

6

Power

This standard rocker switch powers the PN0108 On and Off.

 

Switch

 

 

 

 

6