PN0108 User Manual
(Continued from previous page.)
Heading | Meaning |
|
|
Kill the Power | If this option is selected, the PN0108 waits for the |
| amount time set in the Power Off Delay field (see below), |
| and then turns the Outlet's power OFF when its Power |
| Button is clicked to turn off the power. Turning the power |
| off performs a cold |
| function disables the Reboot checkbox on the main |
| screen. |
|
|
Confirmation Required | If this option is enabled (there is a check in the |
| checkbox), a dialog box comes up asking you to confirm |
| the operation before it is performed. If it is disabled (there |
| is no check in the checkbox), the operation is performed |
| without confirmation. |
|
|
Power On Delay | Sets the amount of time the PN0108 waits after the |
| Power Button is clicked before it turns on the computer |
| attached to the corresponding outlet. |
|
|
Power Off Delay | Sets the amount of time the PN0108 waits after the |
| Power Button is clicked before it shuts down the |
| computer attached to the corresponding outlet. |
| For the System after AC Back option, after the delay time |
| expires, the PN0108 waits another fifteen seconds, then |
| shuts the computer down. |
| The minimum (and default) delay time is 15 seconds. The |
| maximum delay time is 999 seconds. |
|
|
To save your settings, Click Save. To exit without saving your changes, use your browser's Back function to go back to the Main web page, or click another button on the page to go to a different function.
*This function only works with computers capable of a Safe Power Shutdown. See step 3 of Single Stage Installation, page 11, and Chapter 6, Safe Shutdown and Reboot.
Outlet Groups:
Outlet groups allow power control actions to be carried out on the entire group at the same time, rather than repeatedly performing the same action on each individual outlet. You can have four outlet groups per station, and each group can be given a distinctive name. The maximum number of characters for the name is 15.
The bottom Configuration panel lets you select the outlets that you want to put together as an outlet group.