Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.

Side Wall

 

Combustible

or

Non-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

Mantel

 

Combustible

Top

 

 

 

 

 

Facing

k

n

 

 

 

 

 

 

 

 

 

Non-

 

Combustible

m

Facing

 

Minimum Clearances

k

Sidewall to Insert

4-1/2"

l

Side Facing

4-1/2"

m

Top Facing

35" *

n

Mantel

35" *

x

Extension onto Hearth

1-1/4"

* Measured from the base of the insert.

l

x

Mantel Clearances

The maximum mantel depth is 12”.

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.