Avalon Stoves DVS Insert EF II Installation for qualified installers only, Vent Restrictor

Models: DVS Insert EF II

1 42
Download 42 pages 57.46 Kb
Page 15
Image 15
Vent Restrictor

Installation (for qualified installers only)

15

Vent Restrictor

WARNING: Restrictor adjustment should only be done by a qualified installer.

Only those installations determined to be over-drafting require this adjustment. The best indication of over-drafting is a hyper-active flame pattern (flames that move too quickly). If the air shutter is constricted, the flames become short and yellow, yet still very active. Over-drafting may affect the pilot, but this is not the best way to determine over-drafting. Over-drafting is most likely in tall venting configurations (especially if using an “Exhaust Only Re-Line”). Do not over-restrict the vent (this leads to ghosting or lifting flames - reduce restrictor setting).

Vent Installation Adjustment

Plate

Adjustment

Bracket

To Access the Restrictor:

WARNING: Use a glove to protect

Remove the face.

your hand from burns.

To Adjust the Restrictor:

1Determine a restrictor position. Start low (move the restrictor a maximum two positions at a time) and thoroughly test the heater before adjusting further.

2Lift up the adjustment plate and move it so the correct notch falls into the slot on the adjustment bracket.

#4 #5 #6

#3

#2

#1

This restrictor is in position 1 (factory setting).

To adjust, lift up on the

This restrictor is in

adjustment plate and push it back

position 2.

(use pliers if necessary).

 

Vent Installation

Exhaust (3”)

Inlet (3”)

3” dia. Gas Liner

Termination Cap

(Simpson Part # 991)

6-5/8” to 3” & 3” Co- Linear Adapter (Simpson Duravent Part # 923GK)

Manual backgroundManual background Inlet

Exhaust

Use hose-clamps to secure the vent.

Alternative Method: use high-temperature silicone and secure with screws.

Use hose-clamps to secure the vent.

Alternative Method: use high-temperature silicone and secure with screws.