PROGRAMMING

Related Settings

“PROTOCOL” which the choices are REGCOM or VNET

“TX PROTOCOL” which the choices will be MVDR, DALLMEIER, VSI-ADD, VNET “BAUD RATE” 1200- 115.2K

SLAVE

This setting confirgures the Network RJ45 port to be a Slave which is formerly called Regcom or Vnetworker. The Slave uses RS-485 bi-directional communication to the Master unit.

Related Settings “ADDRESS” choices are 1-16

“PROTOCOL” which the choices are REGCOM or VNET “BAUD RATE” 1200 - 115.2K

OFF No data is sent out the Network Port either via RS-232 or RS-485.

ADDRESS

Choices: OFF, 1-16

This select the address or camera number when configured as a slave device. The selections are 1-16 so that the POS/Cash Register is assigned a unique number up to a maximum of 16 to send the data over the RS-485 network back to a Master unit or a Hydra device which then sends all the data to the DVR or PC for recording.

PROTOCOL

Choices: REGCOM or VNET

This setting selects the protocol of the RS-485 Network. There are two protocols to be compatible with two different devices and functions. The REGCOM can be selected for compatibility with the Regcom networking device. The Regcom device can be set for either 9600 or 57600 baud rate to match the installed device settings. However when not using the Regcom device and using only VSI-Pro Max then any baud rate can be set. The Regcom Protocol only has the ability to receive register data only.

The VNET can be configured for compatibility with the Vnetworker or Networker devices. A baud rate of 19200 can be only used for these external devices. However when used with a VSI-Pro Max device and no external Vnetworker or Networker devices are used then any baud rate can be used. The Vnetworker protocol has the ability to receive register data, Program remote VSI-Pro Max devices, receive remote alarming and Time/Date information.

BAUD RATE

Choices: 1200 - 115200 baud rate

This sets the comunication speed for the Network port in all configurations. Care must be given to selecting the proper baud rate for the Type of operation you wish and configuration you set for the VSI-Pro Max.

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.

5.7EXCEPTION REPORTS

EXCEPTION REPORT OVERVIEW

The Exception Report gives you the option to assign an on-screen flag, trigger an alarming device, or send data to another serial device on any questionable transaction that you have preprogrammed into the VSI-Pro Max.

VSI-Pro Max POS / Cash Register Interface

33

Page 33
Image 33
AVE VSI-Pro Max operation manual Exception Reports, Exception Report Overview