If “TOP” is selected which is the default, the data scrolls from the top most line down to the selected number of lines displayed. “T/D” and/or “TITLE” is displayed at the top of the screen. If “BOTTOM” is selected then the data scrolls up from the bottom most line to the top of the screen and “T/D” and/or “TITLE” is displayed at the bottom of the screen.

LINE COMPRESS

NOTE ? Set your Exceptions first before enabling this feature.

The VSI-Pro automatically compresses the spaces in a line first as it reaches 40 characters. With LINE COMPRESS “ON”, the VSI-Pro will additionally remove multiple spaces and then vowels from the text to further compress the display as necessary.

To make this selection, position the arrow in front of “LINE COMPRESS” and press and release “Set”. The arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “Up” or “Down” button, and press “Set” when your choice is displayed. The cursor will stop flashing and you can continue programming.

SPACE COMPRESS

Space Compress allows you select the number of maximum spaces next to each other in a line. The selections are 1,2,3,4,5 and OFF. If you select “1” then if three spaces are shown on the receipt the VSI-Pro will delete 2 and only show 1 space between characters on the video and on the output data to the DVR.

LEFT JUSTIFICATION

When LEFT JUSTIFIED is “ON”, the VSI-Pro will start each line of text with no leading spaces from the left margin of the text display block.

SCROLL DELAY

Scroll delay ensures that lines of text remain on-screen a minimum of 0.5 seconds. This is especially useful with registers that run at a high baud rate, time-lapse VCRs in extended record modes, switchers, or multiplexers. Sometimes, the register can produce characters so quickly that they can scroll up too fast on the screen to be recorded. When SCROLL DELAY is “ON”, the VSI-Pro slows down this data feed just enough to insure that each line of text is recorded.

The choices for SCROLL DELAY are either “ON” or “OFF”. To make this selection, position the arrow in front of “SCROLL DELAY” and press and release “Set”. The arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “Up” or “Down” button, then press “Set” when your choice is displayed. The cursor will stop flashing and you can continue programming.

DISPLAY

You have the choice to globally turn “ON” or “OFF” the complete VSI-Pro text insertion function. This means no data will be visible on the monitor if you select DISPLAY “OFF”. However, if you select the DISPLAY “OFF”, you can still command each exception independently to either display on-screen or not through its program setup menu under “EXCEPTION REPORTS”. You may also choose to enable an alarm output to occur during an exception while not displaying the exception data through the program set-up in the ALARM OUTPUTS menu. With the display “OFF”, the VSI-Pro will still perform all functions as programmed, for example, exception reporting will still function, but the information will not appear on-screen unless programmed to do so in the EXCEPTIONS REPORT menu. Also the data will not show in the history buffer if not displayed.

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.