AVE VSI-Pro Max operation manual Hydra and Regcom, Dipswitch Settings

Models: VSI-Pro Max

1 84
Download 84 pages 12.82 Kb
Page 74
Image 74

HYDRA and REGCOM

APPENDIX M

RS-485 NETWORK DATA CABLE WIRING

(120 Ohm impedance, twisted pair)

RJ-45

RJ-45

 

 

Pin 4

Pin 4

 

 

Pin 5

Pin 5

 

 

Table 8: RS-485 Network Data Cable Wiring

LED STATUS INDICATION

Status light A illuminates whenever data is sent from the Regcom to the master unit. This is the same as Network LED on the VSI-Pro Max.

Status light B illuminates to indicate the Regcom is correcly connectly connected via the RS-485 network to the master unit. This is the same as the Register LED on the VSI-Pro Max

RS-232 Parameters

Baud rate

9600 or 57.6K

 

 

Data bits

8

 

 

Parity

None

 

 

Stop bits

1

 

 

Table 9: Hydra RS-232 Parameters

Network Parameters

Standard

RS-485

 

 

Max line length

4000 ft

 

 

Cable type

120 Ohm twised pair

 

 

Table 10: Network Parameters

Figure 136: VSI-Pro Max Front Panel Figure 137: Hydra / Regcom

Figure 138: Hydra / Regcom

Front Panel

Rear Panel

Dipswitch Settings

 

The following are the rear dipswitch settings for both the Regcom and Hydra. SW1-5 select the address for the Regcom and the communication parameters for the Hydra. SW6 has no function. SW7 has no function for the Hydra but selects Baud rate for the Regcom On- 57.6K, Off 9600 baud. SW8 terminates either device with 120 ohms and should be on for the Hydra and on for the last Regcom in the network.

Regcom

 

 

 

 

 

(Note)

Term

Hydra Functions

Address

 

 

 

 

 

 

On/Off

Input

Output

 

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

 

 

---

Off

Off

Off

Off

Off

Off

----

----

Regcom

VSI-ADD 9600 baud

1

On

Off

Off

Off

Off

Off

----

----

Vnetworker

Vnetworker

2

Off

On

Off

Off

Off

Off

----

----

Vnetworker

MVDR3000/5000

3

On

On

Off

Off

Off

Off

----

----

Regcom

Dallmeier Addr 1-8

4

Off

Off

On

Off

Off

Off

----

----

Vnetworker

Dallmeier Addr 1-8

5

On

Off

On

Off

Off

Off

----

----

Regcom

VSI-ADD 57.6K baud

6

Off

On

On

Off

Off

Off

----

----

TBD

 

7

On

On

On

Off

Off

Off

----

----

TBD

 

8

Off

Off

Off

On

Off

Off

----

----

TBD

 

9

On

Off

Off

On

Off

Off

----

----

TBD

 

10

Off

On

Off

On

Off

Off

----

----

TBD

 

11

On

On

Off

On

Off

Off

----

----

TBD

 

12

Off

Off

On

On

Off

Off

----

----

TBD

 

13

On

Off

On

On

Off

Off

----

----

TBD

Table 11: Hydra / Regcom

14

Off

On

On

On

Off

Off

----

----

TBD

Dipswitch Settings

15

On

On

On

On

Off

Off

----

----

TBD

 

16

Off

Off

Off

Off

On

Off

----

----

TBD

 

 

 

 

 

 

 

 

 

 

 

 

VSI-Pro Max POS / Cash Register Interface

74

Page 74
Image 74
AVE VSI-Pro Max operation manual Hydra and Regcom, Dipswitch Settings