PROGRAMMING

DISPLAY TEXT

Choices: ON, OFF

Press the “Up” or “Down” button to move the cursor to “DISPLAY TEXT” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will not display any exception text on the video output.

OUTPUT TEXT

Choices: ON, OFF

Press the “Up” or “Down” button to move the cursor to “OUTPUT TEXT” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will not send any exception text to the serial printer.

RTS TRIGGERED DELAY

Choices: OFF, 1S, 5S, 10S, 20S, 30S, 1M, 5M, 10M

Press the “Up” or “Down” button to move the cursor to “RTS TRIGGERED DELAY” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed. Selecting “OFF” will give no delay and will trigger the alarm immediately upon RTS closure..

This function introduces a time delay for the RTS Trigger Input before initiating an alarm condition. The alarm must be continuous for the entire time of the delay setting or the time out will be reset. This is useful to connector to cash drawers or safe doors and wait a programmable amount of time before sounding the alarm. Leaving cash drawers or safe doors open are indicative of theft or simple forgetfullness and an alarm condition will deter this behavior.

SET TRIGGERED TEXT

Press the “Up” or “Down” button to move the cursor to “SET TRIGGERED TEXT” and press “Set”. The following sub- menu will appear:

DISPLAY TEXT

OFF

OUTPUT TEXT

OFF

RTS TRIGGERED DELAY OFF

SET TRIGGERED TEXT

EXIT

Figure 75: Set Triggered Text Main-Menu

You can enter 2 lines with 40 alpha numeric text on each line. You can also enter non-printable data (control code) instead of triggered text. Each control code occupies 3 charactors, therefore you can enter 13 control codes in a line. To enter control code, first print up arrow ^ follwed by 2 hex digit. For example, hex code 01 has to be entered like ^ 01. Press “Up” and “Down” simultaneously to exit.

VIDEO LOSS

Choices: Manual, 1s, 2s, 3s, 4s, 5s, 10s, 20s, 30s, 1M

Video Loss allows the VSI-Pro Max to generate an alarm condition when low or lost video occurs. When set for manual the alarm follows the state of the video loss, when set for 1s-1M this means the video must be lost continuously for that period of time before an alarm is triggered. The alarm mode is a timed mode so once the video loss alarm is triggered the alarm time out must expire and get another video loss to retrigger the alarm.

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.