54

Technical Specifications

AXIS 2100 User’s Guide

 

 

 

Appendix E - Technical Specifications

System Requirements - TCP/IP on Windows 95, 98, NT and 2000, as well as Linux, UNIX, Mac and several others. Microsoft Internet Explorer 4.x, or higher (used with Axis’ ActiveX component AXIS Camera Control), or Netscape 4.x or higher.

Network Connection - RJ45 twisted pair cable, or remote connection using any standard serial modem.

Networking - 10baseT Ethernet or 100baseTX Fast Ethernet, TCP/IP, HTTP, FTP, SMTP, NTP, ARP and BOOTP.

I/O Connector - 1 optical-isolated alarm input. 1 digital output (max 24V, 100mA) with programmable digital input/output for remote image storage via FTP or SMTP, pre/post alarm image storage.

Image Updating - Up to 10 frames/second over 10Mbps or 100Mbps networks.

Pre/Post Alarm Buffer - Up to 500kB memory available for pre/post alarm image storage.

Modem Connector - Single 9-pin D-SUB RS-232 connector, max 115 kbps, half duplex

Operating Conditions: - Temp: 40o to 105o F (+5o to +40o C), Humidity: 20-80% RHG.

Approvals - EMC: FCC Class A, EN 55022/1994, EN55024/1998

Safety: EN 60950, UL, CSA.

Metrics: - Height: 1.6” (4.3 cm), Width: 4.0” (10.2 cm), Length: 5.8” (14.7 cm), Weight: 0.55 lb. (0.25 kg) excluding power supply.

Hardware - ARTPEC-1 compression chip; ETRAX-100, including, 32 bit RISC, 100 MIPS CPU, 8 MB RAM, 2 MB FLASH PROM.

Power - External power supply 12V AC, 9.6 VA (PS-D, included), 9-15V AC, min. 10VA, or

9-15V DC, min. 7W.