36AXIS 223M - Event Configuration

Object size, history and sensitivity:

 

Object Size

History

Sensitivity

 

 

 

 

High level

Only very large objects

An object that appears in the region will trigger

Ordinary colored objects on ordinary back-

 

trigger motion detection

the motion detection for a long period

grounds will trigger the motion detection

 

 

 

 

Low level

Even very small objects

An object that appears in the region will trigger

Only very bright objects on a dark back-

 

trigger motion detection

motion detection for only a very short period

ground will trigger motion detection

 

 

 

 

Default value

Low

Medium to High

Medium to High

 

 

 

 

Examples:

Avoid triggering on small objects in the video image by setting the Object Size level to high.

To reduce the number of triggers if there is a lot of movement during a short period of time, select a high History level.

To only detect flashing light, low Sensitivity can be selected. In other cases, a high Sensitivity level is recommended.

Port Status

Under Event Configuration > Port Status there is a list showing the status for the camera’s input and output. This is for the benefit of Operators, who cannot access the System Options section.

Example: If the Normal state for a door push button connected to an input is set to Open circuit - as long as the button is not pushed, the state will be inactive. If the doorbell button is pushed, the state of the input changes to active.

Page 36
Image 36