28AXIS 231D/232D - Event Configuration

Event Configuration

This section describes how to configure the AXIS 231D/232D for alarm handling. The AXIS 231D/232D can be configured to perform actions when defined types of events occur.

Event type

A set of parameters describing how and when the Network Dome Camera is to perform certain actions

 

 

 

Triggered Event page 29

the circumstances that start an event

e.g. at a signal from an external device, such as a door switch or

 

 

a motion sensor

 

 

 

Scheduled Event page 31

the circumstances that start an event

e.g. at a pre-programmed time

 

 

 

Action

what occurs when the event triggers

e.g. uploaded video images to an FTP server, email notification,

 

 

etc.

 

 

 

Event Servers

Event Servers are used for receiving uploaded image files and/or notification messages. To set up Event server connections in your AXIS 231D/232D, go to Setup > Event Configuration > Event Servers and enter the required information according to the selected server type.

Server type

Purpose

Requires information

 

 

 

 

FTP Server

• used for uploading saved images

• Descriptive name of your choice

 

 

• User Name and Password (to FTP server)

 

 

• Upload path e.g. images/

 

 

• Port number e.g. port 21

 

 

• Use passive mode if there is a firewall between

 

 

the dome camera and the FTP server

 

 

• Use temporary file if your FTP server doesn’t

 

 

allow an existing file to be overwritten by a

 

 

new file with the same name

 

 

 

HTTP Server

• used for uploading saved images

• Descriptive name of your choice

 

• used for notification messages

• URL

 

 

 

• User Name and Password (to HTTP server)

 

 

• Proxy address/Proxy port (if required)

 

 

• Proxy User Name and Password (if required)

 

 

 

TCP Server

• used for notification messages

• Descriptive name of your choice

 

 

• User Name and Password (to TCP server)

 

 

• Port number e.g. port 80

 

 

 

 

For details on each setting, please refer to the online help files

which are available

from each web page.

 

 

Note: Pre-trigger and Post-trigger buffers will be lost if the connection to the event server fails.

When the setup is complete, the connection can be tested by clicking the Test button (the connection test will take approximately 10 seconds).

Page 28
Image 28
Axis Communications 231D, 232D user manual Event Configuration, Event Servers