48AXIS 231D/232D - Troubleshooting

Emergency Recovery Procedure

If power or the network connection to the AXIS 231D/232D is lost during the upgrade, the process will fail and the unit will become unresponsive. A flashing red Network LED indicates a failed upgrade. To recover the unit, follow the steps below. The serial number is found on the label on the product casing.

1.Unix/Linux - From the command line, type the following: arp -s <IP address of AXIS 231D/232D> <Serial number> temp ping -s 408 <IP address of AXIS 231D/232D>

Windows - From a command/DOS prompt, type the following: arp -s <IP address of AXIS 231D/232D> <Serial number> ping -l 408 -t <IP address of AXIS 231D/232D>

Note: the ping -lcommand is the lower-case letter (L)

2.If the unit does not reply within a few seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.

3.Open a browser and type in the AXIS 231D/232D’s IP address. In the page that appears, use the Browse button to select the upgrade file to use, e.g. axis231d.bin or axis232d.bin. Then click the Load button to restart the upgrade process.

4.After the upgrade has completed (1-10 minutes), the unit will automatically restart and show a steady green on the Power LED and flashing green or amber on the Network LED.

5.Reinstall the AXIS 231D/232D.

If the emergency recovery procedure does not get the AXIS 231D/232D up and running again, please contact Axis support at www.axis.com/techsup/

Support

If you contact Axis Customer Services, please help us help you resolve your problems expediently by providing a server report, log file and a brief description of the problem.

Server Report - go to Setup > System Options > Support Overview. The server report contains important information about the server and its software, as well as a list of the current parameters.

Log file - go to Setup > System Options > Logs & Reports. The Log file records events within the unit since the last restart of the system and can prove a useful diagnostic tool for troubleshooting.

Page 48
Image 48
Axis Communications 231D, 232D user manual Emergency Recovery Procedure, Support