Hardware Inventory AXIS 2400/2401 Admin Manual

8

AXIS 2400/2401 Rear Panel

Note: The power supply for your AXIS 2400/2401 is country-specif ic. Please check that the type you
are using is correct. See below.
Hardware Inventory
Check the items supplied with your AXIS 2400/2401 agai nst the following list:
Item Title/Variants Part Numbers Item Title/Variants Part Numbers
Video Server AXIS 2400 0092-001-02 Power Supply
(PS-D) Europe 14233
AXIS 2401 (NTSC) 0103-011-02 UK 14234
AXIS 2401 (PAL) 0103-001-02 Australia 14255
Null Modem Cable - 16954 USA 14253
Warranty Document 18640 Japan 14254
Disk Media AXIS Network
Camera CD v2.0 (or
later)
-This Docu-
ment AXIS 2400/2401
Administration
Manual v2.1
19097
Power Supply Connector
A single Jack socket (PS-D) for
connection of the AXIS 2400/2401
power supply. The terminal block
connector provides an auxiliary
connection point for AC or DC
power to the unit.
Network Connector
The AXIS 2400/2401 is designed for 10 Mbps Ethernet and
100 Mbps Fast Ethernet networks and connects to the net-
work via a standard RJ45 connector. Supporting NWAY,
the AXIS 2400/2401 detects the speed of the local net-
work segment and varies the speed of data communication
accordingly (between 10 Mbps and 100 Mbps).
I/O Terminal Block
The I/O Terminal Block connector is located between the two serial ports on the
rear panel and provides the physical interface to one relay switch output, four
digital photo-coupled inputs, and an RS-485 interface. Use this connector for
transmitting data over multi-drop communication lines, RS-485 Pan Tilt devices,
and external triggering - typically associated with CCTV equipment. The connector
can be utilized as an alternative connection point for DC supply to the unit.
RS-232 Serial Connectors
Two 9-pin D-sub connectors providing RS-232 serial con-
nection. Typically used for Pan/Tilt device interface. COM1
is multiplexed with the RS-485 port via the Terminal
Block Connector. COM2 can also be used for connecting a
modem or the AXIS 2191 Audio Module.
POWER
PS-D COM 1 COM 2 ETHERNET
10/100
1 2 3 4 5 6 7 8
910111213141516