Baldor MN1928 Digital inputs, Backplanes, Location, Name, Description, NextMove ES, 96-pin

Models: MN1928

1 126
Download 126 pages 18.49 Kb
Page 60
Image 60

www.supportme.net

5.3.5 Digital inputs 16-19

10

Location

X6

 

 

 

Mating connector: Weidmüller Omnimate BL 3.5/10

 

 

 

 

 

 

Pin

Name

Description

NextMove ES

 

 

 

 

96-pin

 

 

 

 

connector

 

 

 

 

 

 

10

Shield

Shield connection

a32

 

 

 

 

 

 

9

USR GND

Customer power supply ground

 

 

 

 

 

 

 

8

USR GND

Customer power supply ground

 

 

 

 

 

 

1

7

USR V+

Customer power supply

 

 

 

 

 

 

6

USR V+

Customer power supply

 

 

 

 

 

 

 

5

!RST IN

Reset input

c12

 

 

 

 

 

 

4

DIN19

Digital input DIN19

b26

 

 

 

 

 

 

3

DIN18

Digital input DIN18

c25

 

 

 

 

 

 

2

DIN17

Digital input DIN17

c24

 

 

 

 

 

 

1

DIN16

Digital input DIN16

c11

 

 

 

 

 

The BPL010-502 and BPL010-503 opto-isolating cards use different input configurations. Sections 5.3.5.1 and 5.3.5.2 describe the two input types.

5.3.5.1BPL010-502 - Active high inputs

The user power supply connection USR GND is common to all inputs. To activate an input, a voltage must be applied that is sufficient to cause at least 5mA in the input circuit. To ensure that an input becomes inactive, the current must be less than 1mA. The internal pull-up resistor on the NextMove ES allows the input to be left floating when inactive or not being used.

 

 

Backplane & opto-isolator card

 

 

‘X6’

 

 

User

DIN16

 

 

supply

1

 

 

 

24V

 

 

 

 

 

2k2

96

 

 

 

pin

 

 

 

connector

User

USR GND

 

 

supply

8

 

GND

 

TLP521-4

 

 

 

 

NextMove ES

+5V

10k

74AHCT14

MintMT

INX.16

GND

Figure 31 - Digital input circuit (DIN16) with ‘active high’ inputs

5-20 Backplanes

MN1928

Page 60
Image 60
Baldor MN1928 installation manual Digital inputs, Backplanes, Location, Name, Description, NextMove ES, 96-pin, connector