It is important that the correct steps are followed when installing the NextMove ES. This section describes the mechanical installation of the NextMove ES.
You must read and understand this section before beginning the installation.
CAUTION: To prevent equipment damage, be certain that input and output signals are powered and referenced correctly.
CAUTION: To ensure reliable performance of this equipment be certain that all signals to/from the NextMove ES are shielded correctly.
CAUTION: Avoid locating the NextMove ES immediately above or beside heat generating equipment, or directly below water steam pipes.
CAUTION: Avoid locating the NextMove ES in the vicinity of corrosive substances or vapors, metal particles and dust.
The safe operation of this equipment depends upon its use in the appropriate environment. The following points must be considered:
HThe NextMove ES is designed to be mounted in a IEC297 / DIN41494 rack with card frames and guides to support the card.
HThe NextMove ES must be installed in an ambient temperature of 0°C to 40°C (32°F to 104°F).
HThe NextMove ES must be installed in relative humidity levels of less than 80% for temperatures up to 31°C (87°F) decreasing linearly to 50% relative humidity at 40°C (104°F),
HThe NextMove ES must be installed where the pollution degree according to IEC664 shall not exceed 2.
HThere shall not be abnormal levels of nuclear radiation or